Ratings, types, voltages and construction

Voltages

The ACS350 is available in two voltage ranges: 2 = 200 240 V 4 = 380 480 V



Construction

01U or the 03U within the type code indicates the number of input phases for the power and EMC filtering. 01 = 1-phase (200 240V only)
• 03 = 3-phase (200 240V and 380 480V)
• U = EMC filter disconnected, 60 Hz frequency
• (In case the filter is required it can easily be connected.)

 

Notes for Product Selection

General Notes

• 2N: continuous base current at 400C (104F) and 500CC (1200CF). Overload cycle 150% for 1 minute / 10 minutes allowed.
• Continuous output current at 5O0CC (1200C ) shown for 230Vac NEC motor ratings. When used at 500CC (1200C) at input voltages less than 230Vac may require larger drive.
• Current ratings do not change with different supply voltages.
• The rated current of the ACS350 must be greater than or equal to the rated motor current to achieve the rated motor power given in the table.
• Horsepower ratings are based on NEC motor ratings for typical 4-pole motors (1800 rpm). Check motor nameplate current for compatibility. 240Vac Ratings (pricing
3-phase supply voltage 208, 230 or 240 V. The power ratings are valid at nominal voltage, 208Vac at 400C (1040F) or 230Vac at 500C (1200CF). 

Type Code

Nominal ratings

400C (1040F) Continuous Rating 500C (1200F) Continuous Rating Frame Size
I2N A PNHP I2NA PNHP
1-Phase Un = 200040V (200, 208, 230, 240V)

ACS350-01U-02A4-2+J404

2.4

0.5

 

2.2

0.50

R0

ACS350-01U-04A7-2+J404

4.7

1

4.2

1.0

R1

ACS350-01U-06A7-2+J404

6.7

1.5

6.0

1.5

R1

ACS350-01U-07A5-2+J404

7.5

2

6.8

2

R2

ACS350-01U-09A8-2+J404

9.8

3

8.8

2

R2

3-Phase Un = 2000240V (200, 208, 230, 240V)

ACS350-03U-02A4-2+J404 2.4 0.50 2.2 0.50 R0
ACS350-03U-03A5-2+J404 3.5 0.75 3.2 0.75 R0
ACS350-03U-04A7-2+J404 4.7 1 4.2 1 R1
ACS350-03U-06A7-2+J404 6.7 1.5 6.0 1.5 R1
ACS350-03U-07A5-2+J404 7.5 2 6.8 2 R1
ACS350-03U-09A8-2+J404 9.8 3 8.8 2 R2
ACS350-03U-17A6-2+J404 17.6 5 15.8 5 R2

• Mumbai, Maharashtra • Hubli
• Pune, Maharashtra • Coimbatore
• Ahmadabad ,Gujarat • Delhi / New Delhi
• Vapi • Chhotanagpur
• Surat • Kolkata
• Vadodara • Ahmedabad
• Chennai • Bengaluru
• Vishakhapatnam • Bhopal
• Kollam • Bhubaneswar
• Chandigarh • Coimbatore
• Gurgaon • Hyderabad
• Jaipur • Jamshedpur
• Kharghar • Kolkata
• Lucknow • Kochi
• Nagpur • Navi Mumbai
• New Delhi • Puducherry
• Vadodara • Visakhapatnam



• Dubai • Mecca
• Abu Dhabi • Medina
• Oman • Dhaka
• Kuwait • Seeb
• Bahrain • Salalah in Oman
• Qatar • Astana
• Saudi Arabia • Almaty in Kazakhstan
• Nigeria • Mogadishu
• Syria • KhartoumOmdurman
• Tashkent • Dar es Salaam
• Jeddah • Alexandria
• Accra • Nairobi
• Kano • Algiers
• Addis Ababa • Luanda
• Dakar • Tripoli
• UAE • Harare
• Douala • Hargeisa
• Brazil • Jakarta
• Iran • Khartoumomdurman